IcetennialClear Ice Decisions

Field guide

How to Winterize a Commercial Ice Machine for Cold Weather

Service docket

Prepared by Editorial TeamFiled 2026-11-02

Winterizing a commercial ice machine is not the same as switching it off. When a machine sits full of water in a room that can approach or reach freezing, trapped water expands, cracks components, and turns a planned seasonal shutdown into a spring repair bill. The winterization sequence below follows the shutdown and storage instructions that ice machine manufacturers publish in their installation and instruction manuals.

Hoshizaki's KM series installation manual is explicit about the goal: when shutting the icemaker off for an extended time, drain out all water from the water line, remove the ice from the storage bin, clean and dry the bin, and drain the icemaker using air or carbon dioxide to prevent damage to the water supply line at sub-freezing temperatures. The machine stays off until the proper ambient temperature is resumed. Hoshizaki KM-250B installation manual

Note

Easy Ice reports that when ambient air or incoming water falls below 45°F, ice machines develop extended harvest cycles, frozen components, and cracked water lines. Winterization is what stands between a dormant machine and those failure modes. Easy Ice on cold-weather ice maker problems

Decide which shutdown level you need#

Match the procedure to the exposure, not to the calendar:

SituationRequired preparation
Two to three days unused, room stays warmMove the control switch to OFF. Manufacturer guidance says this is sufficient unless sub-freezing temperatures are possible.
Extended shutdown (weeks to a season), heated spaceClean and sanitize, drain the water system, empty and dry the bin per the manual.
Any exposure to sub-freezing temperaturesFull procedure plus draining the supply line and, where the manual directs, blowing the water lines clear with air or carbon dioxide.

The distinction matters because the failure mechanism is physical. Water expands roughly on the order that any frozen water bottle demonstrates; manufacturers warn that the same expansion cracks lines and housings. Easy Ice notes that frozen pipes can stop water from entering the machine, trigger fault beeps, or split open and leak, and that pipes running through unheated areas are the ones that need insulation or drainage. Easy Ice on cold-weather ice maker problems

Step 1: Clean and sanitize before you drain#

Perform the machine's cleaning and sanitizing cycle as part of shutdown, not at restart. Scale that hardens over a dormant season is harder to remove, and residues left in a wet system support slime growth while the machine sits.

  • Run the manufacturer's cleaning procedure for the water system, then the sanitizing procedure.
  • Scotsman's user documentation reminds owners that cleaning frequency and outcome depend on local water and ambient conditions and on ice volume produced; a machine in hard water needs the cleaning cycle as much before storage as during service. Scotsman CU0515 user manual
  • Empty the bin, then wash, rinse, sanitize, and air-dry the bin interior and the scoop. Ice is food under the FDA Food Code, so the bin is a food-contact surface. FDA Food Code

If the machine is heavily scaled, remove the scale first. The dedicated guide to removing scale from a commercial ice machine covers the procedure, and the full cleaning and sanitizing walkthrough applies here unchanged.

Step 2: Remove all ice and drain the water system#

Follow the model-specific steps in your manual. The Hoshizaki KM series procedure illustrates the pattern common to most machines:

  1. Move the control switch to OFF and close the water supply.
  2. On water-cooled models, drain the water-cooled condenser first; the manual gives its own sequence for removing that water.
  3. Drain the water tank by removing the plug at the bottom of the tank, then replace the plug.
  4. Remove every cube from the storage bin.
  5. Clean the bin and let it dry. Hoshizaki requires the bin to be cleaned and dried for long storage. Hoshizaki KM-250B installation manual

Do not improvise the drain path. Pumps, float switches, inlet valves, and evaporator circuits hold water in pockets that gravity alone does not empty. Easy Ice lists inlet valves, float switches, evaporator plates, and water pumps among the components that freeze over when low temperatures meet standing water. Easy Ice on cold-weather ice maker problems

Heads up

The Hoshizaki manual calls for draining the icemaker with air or carbon dioxide at sub-freezing exposure. That step pushes water out of low points gravity draining misses. If you cannot perform it with the equipment the manual describes, schedule a technician for the blow-out rather than skipping it. Hoshizaki KM-250B installation manual

Step 3: Protect the supply line and the room#

Draining the machine does not protect the building plumbing behind it.

  • Insulate exposed supply and drain lines, especially any run through exterior walls, unheated vestibules, or crawl spaces.
  • Close and, where possible, drain the supply valve serving the machine so the last feet of line cannot hold water.
  • Keep the room above the machine's minimum operating temperature where the space remains in use. Scotsman's final check list asks whether the unit sits in a room where ambient temperatures stay above a minimum of 10°C (50°F) even in winter months. Scotsman CU0515 user manual

Easy Ice's technicians recommend a temperature-controlled space around 70–75°F for machines that keep running through winter, with pipe insulation as the companion measure for lines exposed to cold. Easy Ice on cold-weather ice maker problems

Step 4: Document the shutdown#

Write down the shutdown date, the steps completed, the filter model and install date, and the condition of the inlet and outlet pressure readings if the machine has gauges. Filters left in during a shutdown age on the calendar; the filter replacement schedule guide explains how capacity and time both bound cartridge life, so record what went in and when.

Leave the manual, the sanitizing records, and the shutdown note with the machine. The person who restarts it in the spring is often not the person who shut it down.

Step 5: Restart on a checklist, not on a switch#

At restart, reverse the sequence and verify conditions before resuming production:

  1. Confirm room ambient and incoming water are back inside the machine's normal operating ranges. The Hoshizaki KM manual specifies normal ambient of +45°F to +100°F and normal water temperature of +45°F to +90°F, and warns that extended operation outside these ranges affects production capacity. Hoshizaki KM-250B installation manual
  2. Restore the water supply and check for leaks at every connection you drained.
  3. Reinstall a fresh cartridge if the old one spent its capacity or its calendar life in storage.
  4. Sanitize the bin again before returning it to service, and confirm the scoop is clean and stored properly. FDA Food Code
  5. Run the manual's startup and final-check procedure, then watch one full freeze and harvest cycle before loading the bin. Scotsman's documentation includes a final check list for exactly this purpose. Scotsman CU0515 user manual

Discard the first harvest or two after any chemical cleaning or long idle period, and confirm cubes are complete, clear, and free of odor before serving them. If the first cycles produce malformed ice or the machine shuts down on a safety, work through the diagnostic guide to why a commercial ice machine stops making ice in cold weather before calling for service.

Tip

Budget the restart like a maintenance event, not a five-minute task. Easy Ice notes that a full replacement machine can take six to ten weeks to arrive once a failure is diagnosed, which is one more reason to protect the unit you already have through the winter. Easy Ice bar and restaurant guide

When to call a technician#

Use a qualified ice machine technician when the blow-out drain requires equipment you do not have, when the machine sat through a freeze and you suspect split lines or a damaged pump, or when the restart produces leaks, error codes, or repeated safety shutdowns. Bring the shutdown record, the filter history, and the model and serial number. A documented winterization makes the spring diagnosis faster and cheaper, and it protects warranty coverage by showing the manufacturer's storage procedure was followed.

Sources#

Q & A

Frequently asked questions

Can I winterize a commercial ice machine without cleaning it first?
No. The manufacturer's storage procedure assumes the water system is cleaned and the bin is cleaned and dried before shutdown. Residual scale and biofilm are harder to remove after months of sitting, and a wet, dirty bin is a sanitation risk at restart.
Does a short weekend closure need the full winterization procedure?
No. Manufacturer guidance for a Hoshizaki KM series machine says that when the machine is unused for only two or three days, moving the control switch to OFF is sufficient unless the machine will sit at sub-freezing temperatures. Full drainage is for extended shutdowns or any exposure to freezing.
Why drain the water line if the machine is indoors?
Interior rooms can still drop below freezing when heat fails or the space is unheated. Water expands as it freezes, so trapped water can crack supply lines, valves, pumps, and evaporator circuits. Draining removes the water that would do the damage.

Keep reading